THE CONSTRUCTION AND FABRICATED OF A MOBILE DEEP FREEZER

  • Type: Project
  • Department: Mechanical Engineering
  • Project ID: MCE0132
  • Access Fee: ₦5,000 ($14)
  • Pages: 81 Pages
  • Format: Microsoft Word
  • Views: 971
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853
ABSTRACT

This work on the construction and fabrication of a mobile deep freezer revolves around the concept of refrigeration. The concept of refrigeration revolves around the reverse Carnot cycle. This is  a cycle involving isentropic expansion (at the throttling valve), isothermal expansion (at the evaporator), isentropic compression (at the compressor) and isothermal compressor ( at the condenser) Compression raises the temperatures of the refrigerant above that of its natural surrounding so that it can give up its heat in a heat exchanger to a heat sink such as air or water (condenser). Expansion lowers the refrigerant temperature below the temperature that is to be produced inside the cooling compartment.


TABLE OF CONTENT
Title page
Approval page
Dedication 
Acknowledgment
Abstract

Chapter one: 
Introduction

Chapter Two: 
Literature Review

Chapter Three:
Design Analysis and Calculations
3.1   Determination and choice of condenser and Evaporator temperature.
3.2   Cooling Load Calculation
3.3   Flow Rate
3.3.1Mass flow rate
3.3.2Ton of Refrigeration
3.3.3Volume flow rate
3.4   Determination of Compressor size
3.5   Determination of pipe size and length
3.5.1Comparing the velocities for different pipe size.
3.5.2Summary table.

Chapter Four: 
Construction Details 
4.1  Material Selection
4.2  Sequence of operation
4.3  Assembly

Chapter Five: 
Cost Analysis

Chapter Six: 
Recommendation
6.1   Maintenance and use Instructions
6.1.1Condenser Maintenance
6.1.2Defrosting
6.1.3Other Instructions
6.1.4Common Complaints, Causes and Remedy

Chapter Seven: 
Refrigerants
7.1  Requirements for refrigerants
7.2  Identifying Refrigerants by number
7.3  Halide refrigerants
7.4  Grouping and Classification of refrigerants
7.5  Group one Refrigerants
7.6  R-12 Dichlorodi Fluoromethane (ccl2f2)
7.7  R-22 Monochlorodi fluoromethane (CHCLF2)
7.8  R-11 Trichloromono fluoromethane (CCL3F)
7.9  Azeotropic Mixtures
7.10 R-500 Refrigerant
7.11 R-502 Refrigerant (R-22 + R-115) (CHCLF2/CCLF2 CF3)
7.12 R-503 Refrigerant (R-23 +R-13) (CHF3/CCLF3).
7.13 R-504 Refrigerant (R-32 +R115) (CH2F2 (F3 CCLF2)
7.14 Group  two refrigerants
7.15 R- 717 Ammonia (NH3)
7.16 Group three refrigerants
7.17 Expendable Refrigerants
7.18 Water  as a Refrigerants
7.19 Refrigerant Cylinders
7.20 Color code for refrigerants cylinders

Chapter Eight: 
Conclusion
Reference.

THE CONSTRUCTION AND FABRICATED OF A MOBILE DEEP FREEZER
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Mechanical Engineering
  • Project ID: MCE0132
  • Access Fee: ₦5,000 ($14)
  • Pages: 81 Pages
  • Format: Microsoft Word
  • Views: 971

500
Leave a comment...

    Related Works

    ABSTRACT This  wrote  up is a detail of the processes for the physical realization of the  design and construction  of mobile deep freezer. It is divided into chapters which discussed expensively the practical  refrigeration cycle  with  rull attention  given to design factors working principals and choice of material.  Also considered... Continue Reading
    ABSTRACT This wrote up is a detail of the processes for the physical realization of the design and construction of mobile deep freezer. It is divided into chapters which discussed expensively the practical refrigeration cycle with rull attention given to design factors working principals and choice of material. Also considered were fabrication... Continue Reading
    DESIGN AND FABRICATION OF MOBILE DEEP FREEZER ABSTRACT This wrote up is a detail of the processes for the physical realization of the design and construction of mobile deep freezer. It is divided into chapters which discussed expensively the practical refrigeration cycle with rull attention given to design factors working principals and choice of... Continue Reading
    ABSTRACT This write up is a detail of the process and information of plan for the physical realization of the construction of the 1M3 mobile deep freezer. It is divided into chapters, which discussed extensively the practical refrigeration cycle with full attention given to design factors working principle and choice of material. The method used... Continue Reading
    ABSTRACT This write up is a detail of the process and information of plan for the physical realization of the construction of the 1M3 mobile deep freezer. It is divided into chapters, which discussed extensively the practical refrigeration cycle with full attention given to design factors working principle and choice of material. The method used... Continue Reading
    ABSTRACT This write up is a detail of the process and information of plan for the physical realization of the construction of the 1M3 mobile deep freezer. It is divided into chapters, which discussed extensively the practical refrigeration cycle with full attention given to design factors... Continue Reading
    ABSTRACT The need for an authentic and reliable report relating to the design and construction of 80cm x 70cm x 50cm mobile deep freezer is inevitable. It should be a top priority of every individual in order to avoid huge expenditure in purchase to foreign ones. Its for this reason that this report is written for the benefit of those who are... Continue Reading
    ABSTRACT  The need for an authentic and reliable report relating to the design and construction of 80cm x 70cm x 50cm mobile deep freezer is inevitable. It should be a top priority of every individual in order to avoid huge expenditure in purchase to foreign ones. Its for this reason that this report is written for the benefit of those who are... Continue Reading
    ABSTRACT  Mechanical Engineering Department of the named Institute has many non – operational malhiues. Sequel to the fact, maintenance was poorly excuted which resulted to the breakdown deep freezer. Quality and effectiveness of machine maintenance were well observed. Also, a minimized maintenance and a highly successful  repair was... Continue Reading
    ABSTRACT Mechanical Engineering Department of the named Institute has many non – operational malhiues. Sequel to the fact, maintenance was poorly excuted which resulted to the breakdown deep freezer. Quality and effectiveness of machine maintenance were well observed. Also, a minimized maintenance and a highly successful repair was adopted.... Continue Reading
    Call Us Get this work