ABSTRACT


A Linear Variable Differential Transformer (LVDT) was constructed having a primary

winding of 245 turns and two secondary windings of 100 turns each. The device
was calibrated with a graduated cylindrical rod. The graduated rod when
inserted between the hollow tube which has the windings gave output voltages of
±0.046V, ±0.51V, ±0.088V, ±0.155V, ±0.271V and ±0.395V for displacements of
±0.00cm, ±2.00cm, ±4.00cm, ±6.00cm, ±8.00cm and 10.00cm respectively. The
device when used for measurement shows that there is increase in output voltage
with increase in displacement and vice versa.


TABLE OF CONTENTS

xi


CHATER ONE

1.0 Introduction 1

1.1 Justification 2

1.2 Scope of the study 3

1.3 Aim and objective 4

CHAPTER TWO

2.0 Literature review 5

2.1 Historical background of LVDT 5

2.1.1 Development of LVDT 6

2.2 Transducers 12

2.3 Make-up of the LVDT 13

2.4 Displacement measurement with LVDT 14

2.5 How to connect LVDTs 16

2.6 Advantages and disadvantages of LVDT 19

2.6.1 Advantages 19

2.6.2 Disadvantages 20


CHAPTER THREE

3.0 Construction and Testing 21

3.1 Materials 21

3.2 Construction 21

3.3 Testing and Calibration 22


CHAPTER FOUR

4.0 Result 24


CHAPTER FIVE

5.0 Discussion, Conclusion and Recommendation 26

5.1 Discussion 26

5.2 Conclusion 27

5.3 Recommendation 27

Reference 28

Appendix 29


CONSTRUCTION AND CALIBRATION OF A LINEAR VARIABLE DIFFERENTIAL TRANSFORMER (LVDT)
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Physics
  • Project ID: PHY0041
  • Access Fee: ₦5,000 ($14)
  • Chapters: 5 Chapters
  • Pages: 36 Pages
  • Methodology: Scientific Method
  • Reference: YES
  • Format: Microsoft Word
  • Views: 1.1K

500
Leave a comment...

    Related Works

    ABSTRACT A Linear  Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
    ABSTRACT A Linear  Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
    ABSTRACT  This project write up of a step – down transformer from 220v to 24v:12v, this is to expose what a transformer is all about and its important and uses. The aim of the project, step-down transformer is to show Electrical and Electronics Engineering, could step-down the voltage from 220v to 24:12v, and fro this project write up.... Continue Reading
    ABSTRACT Transformer is one of the indispensable devices mostly in Electric Power Transmission, Transformer Step-down or Step-up, the output voltage/current to the design requirement. This project was meant to show the necessary step and methods of designing and constructing a typical step-up auto transformer with tapping. In this project, we... Continue Reading
    ABSTRACT  This project write up of a step – down transformer from 220v to 24v:12v, this is to expose what a transformer is all about and its important and uses. The aim of the project, step-down transformer is to show Electrical and Electronics Engineering, could step-down the voltage from 220v to 24:12v, and fro this project write up.... Continue Reading
    ABSTRACT This is a technical project write-up design and construction were carried out by me with deep intensive and extensive research work. I all give credit to the authors of the textbooks whose I referred to in the cause of writing this project and its subsequent design and construction. In this project, I shed light on the basic principle of... Continue Reading
    ABSTRACT  This is a technical project write-up design and construction were carried out by me with deep intensive and extensive research work.  I all give credit to the authors of the textbooks whose I referred to in the cause of writing this project and its subsequent design and construction. In this project, I shed light on the basic principle... Continue Reading
    ABSTRACT This is a technical project write-up design and construction were carried out by me with deep intensive and extensive research work under the strict supervisor of Engr K.C Ugwu.  I all give credit to the authors of the textbooks whose I referred to in the cause of writing this project and its subsequent design and construction. In this... Continue Reading
    ABSTRACT This project work-up deals on the design and construction of a single phase step down nations fermor, with raking IKVA, 240V/11OV, 80V 12U, 6V. It is a multi-circuit transformer that has one input as the primary and tappins to produce the output (secondary). It is considered as a single coil in series with the supply and a common coil to... Continue Reading
    ABSTRACT This project work-up deals on the design and construction of a single phase step down nations fermor, with raking IKVA, 240V/11OV, 80V 12U, 6V. It is a multi-circuit transformer that has one input as the primary and tappins to produce the output (secondary). It is considered as a single coil in series with the supply and a common coil to... Continue Reading