ABSTRACT
The purpose of the project is to study the effect of liquid flow rate and gas flow rate on the pressure drop in a packed absorption tower and also to repair and restore the packed absorption tower to good working condition.

Trouble shooting revealed that the exit drain value was broken due to carelessness on the part of former user of the equipment.  We had to carry out glassblowing operations using borosilicate glass to construct another value.  Once this was done pressure build up within the tower was restored for absorption operation to take place.
A plot of log DO/H against log a superficial gas velocity gave 2.0774 2.3037 and 1.4940 respectively for slopes at varied superficial liquid velocity.

We concluded that increase in gas flow rate lead to increase in pressure drop since the graph obtained is linear.  There was a drop in slope from lower liquid rate to higher as operation neared flooding condition.  This means that industrially more cost is alluded to pumping operation to be successful. 
 
TABLE OF CONTENT
Title
Letter of transmittal
Approval page
Dedication
Acknowledgement
Abstract
Table of content

CHAPTER ONE
INTRODUCTION
1.2 Objectives of the project

CHAPTER TWO
2.0 Literature review
2.1 Pressure drop
2.3 Loading and flooding
2.4 Description of tower
2.7 packing characteristic 
2.7.3 Water pump operation
2.8 Design procedure of tower
2.8.2 Selection of solvent

CHAPTER THREE
3.0 Experiment procedure
3.1 Glass  blowing process and procedure
3.1.1 General physical properties of glass
3.1.2 General chemical properties of glass
3.2 Borosilicate glass properties
3.3 Construction of drain value 

CHAPRER FOUR
Data analysis
Discussion

CHAPETR FIVE
Conclusion
Recommendation 
References
Appendix 1: summary of calculation
Graph  11: plot of log DP/H vs log a 46
Appendix 111: cost of repairing equipment 49
Appendix 111: scale drawing of packing absorption tower.
 

THE EFFECT OF LIQUID FLOERATE AND GAS FLOWRATE ON A PACKED ABSORPTION TOWER AND REPAIR OF EQUIPMENT
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Chemical Engineering
  • Project ID: CNG0294
  • Access Fee: ₦5,000 ($14)
  • Pages: 58 Pages
  • Format: Microsoft Word
  • Views: 744

500
Leave a comment...

    Related Works

    ABSTRACT The effect of liquid flow rate, pipe size (diameter) and pipe orientation (inclination) on liquid hold-up was investigated. Liquid flow rate between 500 STB/day and 5000 STB/day was studied. An oil of 25˚API at an average temperature of 175˚F, a gas gravity of 0.65, water cut of 25% with water gravity of 1.07 and containing no free gas... Continue Reading
    ABSTRACT In order for the government of Kenya to meet its fiscal objectives, it is necessary that county government effectively be able to spend budgeted provisions to the highest levels. Government officers need to understand the importance of being able to fully utilize funds as budgeted and as efficiently as possible so as to have an impact to... Continue Reading
    TABLE OF CONTENT Cover page                                                                                          Title... Continue Reading
    TABLE OF CONTENT Cover page                                                                                          Title... Continue Reading
    ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids. It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
    ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids.  It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
    ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids. It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
    ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids.  It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
    ABSTRACT This research project, studies the effect of poor maintenance of art studio tools, equipment and machinery on the teaching and learning of art in tertiary institution, with special focus on I. M. T. ceramic studio. The purpose of the study is to identify the various ways in which poor maintenance of studio equipment affects students... Continue Reading
    ABSTRACT This research project, studies the effect of poor maintenance of art studio tools, equipment and machinery on the teaching and learning of art in tertiary institution, with special focus on I. M. T. ceramic studio.  The purpose of the study is to identify the various ways in which poor maintenance of studio equipment affects students... Continue Reading
    Call Us Get this work