CONSTRUCTION OF AUTOMATIC WATER LEVEL CONTROLLER FOR BOTH OVERHEAD AND UNDERGROUND TANKS

  • Type: Project
  • Department: Electrical Engineering
  • Project ID: ELE0482
  • Access Fee: ₦5,000 ($14)
  • Pages: 70 Pages
  • Format: Microsoft Word
  • Views: 195
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

ABSTRACT
Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized. Several circuits are put together to ensure proper working of this design, and the block diagram includes the supply unit, the micro-processor unit, the sensor unit, the display unit and the pump drives unit. The power unit is responsible for turning on the entire circuit. Some components are used to set up power unit and they include; a 15v step down transformer, a bridge rectifier circuit, a smoothening capacitor and a voltage regulator IC. The microprocessor (AT89S50) controls virtually all the actions carried out in this design. (AT89S50) is used in the design. The sensor unit is responsible for sensing the level of water and transfer the current position of water to the microprocessor. The display unit in the circuit is use to physically show the current position of water in the tank, the properties of seven segment display are been used.


TABLE OF CONTENT

Cover page- - - - - - - - - - - - -i
Title page - - - - - - - - - - - -ii
Certification - - - - - - - - - - - -iii
Dedication - - - - - - - - - - - -iv
Abstract - - - - - - - - - - - --v
Table of content - - - - - - - - - - - -vi
List of figure - - - - - - - - - - - -vi
List of table - - - - - - - - - - - -x

CHAPTER ONE
1.0 INTRODUCTION- - - - - - - - - - -1
1.1 background - - - - - - - - - - -1
1.2 aims and objective - - - - - - - - - -2
1.3 scope of the study- - - - - - - - - -3
1.4 constrains- - - - - - - - - - - -3
1.5 limitations of the project- - - - - - - - -4
1.6 block diagram- - - - - - - - - - -4
1.7 project report organization- - - - - - - - -5

CHAPTER TWO
LITERATURE REVIEW
2.0 review- - - - - - - - - - - -6
2.1 sensors- - - - - - - - - - - -7

CHAPTER THREE
METHODOLOGY
3.00 Project block diagram- - - - - - - - -11
3.01 fluid level detector - - - - - - - - - -11
3.02 system analysis - - - - - - - - - - -12
3.03 step-down transformer- - - - - - - - -12
3.04 transformer circuit representation- - - - - - - -13
3.05 diodes- - - - - - - - - - - -13
3.06 LED- - - - - - - - - - - - -15
3.07 Bridge rectifier- - - - - - - - - - -17
3.08 Voltage regulators- - - - - - - - - -18
3.09 Resistors- - - - - - - - - - - -19
3.10 Transistors- - - - - - - - - - -22
3.11 Relays- - - - - - - - - - - -24
3.12 Piezo electric buzzer- - - - - - - - - -25
3.13 Hardware component- - - - - - - - - -26
3.14 Power supply unite- - - - - - - - - -27
3.15 Display unite- - - - - - - - - - -27
3.16 Input interface design- - - - - - - - - -28
3.17 Pump control segment- - - - - - - - -29
3.18 Input interface design - - - - - - - - -30
3.19 Sensor unit- - - - - - - - - - -30
3.20 Micro-processor unit - - - - - - - - - -31

CHAPTER FOUR
4.01 Overview of the project- - - - - - - 38
4.02 Software design- - - - - - - - - 40
4.03 Software development - - - - - - - 40
4.04 Translator- - - - - - - - - - 41
4.05 Linker/loader- - - - - - - - - 42
4.06 Debugging- - - - - - - - - - 43
4.07 Development process- - - - - - - - 43
4.08 System control program steps- - - - - - 44
4.09 Program- - - - - - - - - - 45

CHAPTER FIVE
SYSTEM TESTING AND IMPLIMENTATION
Test plan and test data- - - - - - - - - -50
5.00 Component test- - - - - - - - - -49
5.01 System test- - - - - - - - - -50
5.02 Transformer test - - - - - - - - -50
5.03 Other test- - - - - - - - - - -51
5.04 Experimented value vs. actual values- - - - - -51
5.05 Performance evaluation- - - - - - - -52
5.06 Packaging- - - - - - - - - - 54
5.07 Bill of engineering measurement and evaluation- - - 53
5.08 conclusions- - - - - - - - - - 54
5.09 Problem encountered - - - - - - - -55
5.10 Recommendations- - - - - - - - -56
5.11 REFFERENCE-- - - - - - - - - -57
CONSTRUCTION OF AUTOMATIC WATER LEVEL CONTROLLER FOR BOTH OVERHEAD AND UNDERGROUND TANKS
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Electrical Engineering
  • Project ID: ELE0482
  • Access Fee: ₦5,000 ($14)
  • Pages: 70 Pages
  • Format: Microsoft Word
  • Views: 195

500
Leave a comment...

    Related Works

    CONSTRUCTION OF AUTOMATIC WATER LEVEL CONTROLLER FOR BOTH OVERHEAD AND UNDERGROUND TANKS ABSTRACT Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When... Continue Reading
    ABSTRACT The very fundamental reasons behind this project assignment is to expose student to the very important aspect of private and independent research work not only theories but also subsequent translation of the theoretical research work into a particular function system. The project construction of automatic fence light controller has been... Continue Reading
    ABSTRACT  The very fundamental reasons behind this project assignment is to expose student to the very important aspect of private and independent research work not only theories but also subsequent translation of the theoretical research work into a particular function system. The project construction of automatic fence light controller has been... Continue Reading
    Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized. Several... Continue Reading
    CHAPTER ONE INTRODUCTION 1.1 Background Information Electricity is a general term comprising of a variety of phenomena resulting from the presence and flow of electric charge. These include many phenomena, such as lightning,... Continue Reading
    CHAPTER ONE INTRODUCTION 1.1Background Information Electricity is a general term comprising of a variety of phenomena resulting from the presence and flow of electric charge. These include many phenomena, such as lightning, static... Continue Reading
    ABSTRACT  T-junction traffic light controller is such a device that will play a significant role in controlling traffic at junctions, to ease the expected increased rush at such junctions and reduce to minimum disorderliness that may arise, as well as allowing the pedestrians a right of the way at intervals rather than being struck down when in a... Continue Reading
    CHAPTER ONE INTRODUCTION Water is an indispensable and inevitable substance to all living things due to its usability and high priority among other substance and materials. Provision of large volume of waters essential due to its significant purpose, which therefore called for a means by which sufficient, and good quality water can be obtained.... Continue Reading
    ABSTRACT An investigative study was carried out to determine the bacteriological qualities of borehole water samples in halls of residence in the University of Benin, Ugbowo Benin City. A total of five water samples were collected from the the various halls of residence in the school. Bacteriological analysis was carried out using standard... Continue Reading
    ABSTRACT An investigative study was carried out to determine the bacteriological qualities of borehole water samples in halls of residence in the University of Benin, Ugbowo Benin City. A total of five water samples were collected from the the various halls of residence in the school. Bacteriological analysis was carried out using standard... Continue Reading
    Call Us Get this work