DESIGN OF A WATER STORAGE AND TRANSMISSION SYSTEM FOR WASTEWATER REUSE

  • Type: Project
  • Department: Civil Engineering
  • Project ID: CVE0051
  • Access Fee: ₦5,000 ($14)
  • Chapters: 5 Chapters
  • Pages: 65 Pages
  • Format: Microsoft Word
  • Views: 1.1K
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853
ABSTRACT
This research is focused at designing of water storage facilities of size 875,000 litres (750,000 litres for underground water storage, and 125,000 Litres for elevated steel tank) of treated wastewater and its transmission system for the storage and re-use of treated wastewater. The project is aimed to structurally design water storage facilities and its transmission system from the reservoir to the overhead tank for the re-use of treated wastewater in Covenant University. The design works was divided into two major parts namely: Transmission system design, and water storage facility Design. Transmission design was divided into two, which are the field activities, and the software activities. Magellan eXplorist 350H North America GPS (Global Positioning System) was used for the field activities, it was used to determine coordinates (Longitudinal and Latitudinal) of various location of points in the university campus, its key usage was to determine the lowest and the highest elevation points on campus, the highest elevated coordinate point was located in between the male postgraduate hall of residence and the postgraduate cafeteria, and the lowest elevated point was at the existing wetland which is directly opposite Daniel’s hall in the campus. The software used for transmission system is WaterCAD, which was used to design the flow path network from the lowest elevation to the highest elevation point. The water storage facility design software used are Staad pro., Orion, and AutoCAD. Staad pro. Was used to analyse and design for the underground water tank, and the elevated steel water tank, while Orion software was used for concrete design and it was used to detail the underground water tank. The result gotten from all the design software were imported to AutoCAD software for editing, scaling, and proper output result.
DESIGN OF A WATER STORAGE AND TRANSMISSION SYSTEM FOR WASTEWATER REUSE
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Civil Engineering
  • Project ID: CVE0051
  • Access Fee: ₦5,000 ($14)
  • Chapters: 5 Chapters
  • Pages: 65 Pages
  • Format: Microsoft Word
  • Views: 1.1K

500
Leave a comment...

    Related Works

    ABSTRACT This research is focused at designing of water storage facilities of size 875,000 litres (750,000 litres for underground water storage, and 125,000 Litres for elevated steel tank) of treated wastewater and its transmission system for the storage and re-use of treated wastewater. The project is aimed to structurally design water storage... Continue Reading
    ABSTRACT The aim of the present study is to know the effect of wastewater (sewage) discharge on the quality water in Ikole-Ekiti, Ekiti State Nigeria. The community discharges wastewater which affect the water quality with most of the wastewater coming from domestic wastewater. Associated with the development of the area, the increase of... Continue Reading
    ABSTRACT The aim of the present study is to know the effect of wastewater (sewage) discharge on the quality water in Ikole-Ekiti, Ekiti State Nigeria. The community discharges wastewater which affect the water quality with most of the wastewater coming from domestic wastewater. Associated with the development of the area, the increase of... Continue Reading
    ABSTRACT The development of any nation and its economy at large is centred on reliable and efficient power supply. Many developing nations are yet to actualise this feat, and therefore, there is need to strategize to meet the ever-rising demand for energy. Battery-based inverter systems have over the years provided additional power supply to... Continue Reading
    ABSTRACT The 20000 liters storage tank was constructed for effective storage and conservation of third with three (3) mild steel sheet of 14 gauge (2mm) thickness.  The construction started by marketing out 1½ (One and half) mild steel of 2440 Mm by 113Mmusing metal meter rule and critter the already market out dimension underwent cutting with a... Continue Reading
    ABSTRACT The 20000 liters storage tank was constructed for effective storage and conservation of third with three (3) mild steel sheet of 14 gauge (2mm) thickness. The construction started by marketing out 1½ (One and half) mild steel of 2440 Mm by 113Mmusing metal meter rule and critter the already market out dimension underwent cutting with a... Continue Reading
    ABSTRACT The 20000 liters storage tank was constructed for effective storage and conservation of third with three (3) mild steel sheet of 14 gauge (2mm) thickness. The construction started by marketing out 1½ (One and half) mild steel of 2440 Mm by 113Mmusing metal meter rule and critter the already market out dimension underwent cutting with a... Continue Reading
    ABSTRACT Billing is a critical function of most Water Boards especially towards sending the bill to their consumers. Most problems, currently seen, result from the manual processes followed. Calculation errors, delays in system updating and bill sending, also report tracking issues are the major problems that water boards find difficult to find... Continue Reading
    ABSTRACT Microcontroller based remote control system is a project design of a system that uses infra red transmission and reception principle to switch on or off other appliances. It is a wireless mode of switching appliances to a desired state. When a number is pressed in the transmitter section, the receiver section decodes the signal and... Continue Reading
    ABSTRACT Microcontroller based remote control system is a project design of a system that uses infra red transmission and reception principle to switch on or off other appliances. It is a wireless mode of switching appliances to a desired state. When a number is pressed in the transmitter section, the receiver section decodes the signal and... Continue Reading
    Call Us Get this work