Assessment of Radiation Dose to Patients During Single Photon Emission Computed Tomography (Spect) 99mtc-Sestamibi Myocardial Perfusion Imaging (Mpi) In Niamey- Niger.

  • Type: Project
  • Department: Medical Physics
  • Project ID: MEP0003
  • Access Fee: ₦5,000 ($14)
  • Pages: 110 Pages
  • Format: Microsoft Word
  • Views: 189
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

ABSTRACT

Radiation absorbed dose for patients undergoing myocardial perfusion has been calculated for technetium-99m Hexakis-2-methoxy-2-methylpropyl-isonitrile (99mTcSestamibi) at the Nuclear Medicine Department of Abdou Moumouni University. Thirty patients were scanned and image quantification was achieved using MedisoInterViewXP® software. An activity of370 MBq (10 mCi) of 99mTc-Sestamibi was administered for stress and 1110 MBq (30 mCi) for rest. A 256 x 1024 matrix size and a speed of 250 mm per minute were used to acquire the whole body image at 10 minutes, 2 hours and 4 hours after injection of 99mTc-Sestamibi for heart, liver and kidneys quantifications and 10 minutes, 20 minutes and 2 hours for urinary bladder quantification. The activities of the heart, liver, kidneys and urinary bladder were determined using the conjugate view method.

 

The uptake of 99mTc-Sestamibi in the heart, liver and kidneys were respectively 2.17%, 6.53% and 5%, 10 minutes after injection and were in good agreement with the work of Wacker’s et al of respectively 1.5±0.4%, 5.9±2.9% and 10.6±2.2% 5 minutes after injection. The cumulative activities for the heart, liver, kidneys and urinary bladder were respectively30.81MBq/h, 74.98MBq/h, 39.09MBq/h, 136.25MBq/h for the stress and 86.78MBq/h, 244.77MBq/h, 108.76MBq/h and 338.80MBq/h for the rest. The difference in the absorbed dose values obtained was less than 10% except for kidneys which was about 15% for both female and male patients. Both methods found a relatively high absorbed dose per unit of injected activity (mGy/MBq) for urinary bladder and ovaries as target-organs for female patients. Also the uncertainties were in the good agreement according to Stabin.

Assessment of Radiation Dose to Patients During Single Photon Emission Computed Tomography (Spect) 99mtc-Sestamibi Myocardial Perfusion Imaging (Mpi) In Niamey- Niger.
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Medical Physics
  • Project ID: MEP0003
  • Access Fee: ₦5,000 ($14)
  • Pages: 110 Pages
  • Format: Microsoft Word
  • Views: 189

500
Leave a comment...

    Related Works

    ABSTRACT Radiation absorbed dose for patients undergoing myocardial perfusion has been calculated for technetium-99m Hexakis-2-methoxy-2-methylpropyl-isonitrile (99mTcSestamibi) at the Nuclear Medicine Department of Abdou Moumouni University. Thirty patients were scanned and image quantification was achieved using MedisoInterViewXP® software. An... Continue Reading
    This study sought to equip clinician’s on the imaging modality of choice between CT and MRI in the diagnosis of brain tumor. The comparison of the two imaging modalities was accessed using biopsy as goal standard. This research study involved 40 patients who underwent CT, MRI and biopsy one at a time in National hospital, Abuja. Data were... Continue Reading
    KNOWLEDGE AND AWARENESS OF RADIATION EXPOSURE AND SAFETY PRACTICE AMONG PATIENTS UNDERGOING MEDICAL IMAGING IN 3 SELECTED HOSPITALS IN THE F.C.T CHAPTER ONE INTRODUCTION 1.1      Background of the study The use X-rays in imaging modalities such as Computed Tomography (CT scans) and mammography to diagnose injury and illness is on the increase... Continue Reading
    ABSTRACT Sphenoid sinus is surrounded by critical structures and this can make sphenoid sinus surgeries very dangerous. The aims of this research were to study the anatomical relationships between the sphenoid sinus and their important adjacent neurovascular structures using the multiplanar reconstruction technique and to measure some important... Continue Reading
    Spleen is enlarged in a variety of clinical conditions including infectious,  infiltrative, immunologic and malignant states. Evaluation of splenic size is  important in every physical examination of the abdomen by a physician. Determination of its size by palpation can be extremely inaccurate because  spleen is never palpable till it is... Continue Reading
    ABSTRACT Background: Computed tomography has become an important tool in medical imaging to supplement conventional x-rays examination and ultrasonography. Aim: To describe the pattern of abdomino-pelvic computed tomography findings in the adult Nigerian population. (A case study EKO Hospital, Ikeja). Patients and Method: A retrospective study of... Continue Reading
    ABSTRACT TABLE OF CONTENT Title Page i Approval Page ii Certification iii Dedication iv Acknowledgement v Abstract vi Table of Contents vii List of Tables ix List of Figures x CHAPTER ONE: INTRODUCTION 1.1 Background of Study 1 1.2 Statement of Problem 3 1.3 Objectives of the Study 3 1.4 Significance of the Study 4 1.5 Scope of Study 4 1.6... Continue Reading
                                                                ABSTRACT Various researchers who have carried out national and international surveys have reported wide variations in patient dose arising from specific x-ray examinations. This study aims to measure and evaluate the average entrance surface dose associated... Continue Reading
    ABSTRACT Various researchers who have carried out national and international surveys have reported wide variations in patient dose arising from specific X-ray examinations. This study intends to quantify and evaluate, by means of thermo luminescence dosimeter (TLD) chips, the average radiation dose to the patients undergoing pelvic x-ray... Continue Reading
    ABSTRACT  The rapid growing number of FM stations with their corresponding antennas have led to an increase in the concern of the potential health risks that may arise as a result of exposure to RF radiations. The main objective of this research was to develop and validate a predictive model with real time measured data for FM antennas in Ghana.... Continue Reading
    Call Us Get this work